10/29/1998 Rev. 0.2 TRANE Tracer Summit Control System Introduction of HVAC Water-Side System Chillers Types & Chilled Water Systems Concept of Ice Storage System Cooling Towers & Condenser Water System Heat Recovery Chillers & Warm Water System Trane Tracer Summit Q & A Contents Temperature Ranges of HVAC Supply Water Why we need so many different HVAC water systems? 7oC Chilled Water 8oC Chilled Water Sub-zero Ice Chilled Water Condenser Water 37oC Warm Water (Heat Recovery) 90oC Hot Water Examples of Critical Systems—MAU, UPW, & PCW Concept of HVAC Building Envelope Cooling Loads OA Make-up % Fab & Room Pressurization Infiltration Exfiltration Air Abatement General Exhaust Solar Heat Ventilation Process Tools Equipment Generated Heats Process & Test Tools Facility & Utility Systems Office OA Equipment Illumination Kitchen & Cafeteria Human Body Temperature & Humidity Control Spec Heating Refrigerating Heat Rejection Air Conditioning Differed by Building Envelope Fab, Support HPM CUP, Office Concept of Heat Rejection Cycle Heat Rejected by Atmosphere Cooling Tower Fan Condenser Water Pumps Chiller Compressor with Refrigerant Chilled Water Pumps Cooling Coils AHU FCU Fans Solar Loads OA Loads Internal Loads 滾雪球? Makeup Air Unit (MAU) Construction HVAC Water Requirement for Dehumidified Cooling & Heating 35oC WWS/WWR 5oC CHS/CHR 5oC CHS/CHR 35oC WWS/WWR Pre-Filter 35% Medium Filter 85% Pre-Heat Coil Carbon/Chemical Filter (Option) Cooling Coil Humidifier Dehumidifier Coil Re-heat Coil HEPA Filter 99.97%@o.3um Damper ROS/ROR Cool-fog VFD Supply Fan with Inverter Ballroom Pressure Control Condenser Water System Schematic VFD 5CH-CH-01 WWT drain VFD VFD VFD VFD VFD WWT drain VFD VFD CDW CT-02 CDW CT-01 CDW CT-03 CDW CT-04 CDW CT-05 CDW CT-06 CDW CT-07 CDW CT-08 9CH-CH-14 9CW-P-15 5CW-P-01 5CH-CH-02 5CH-CH-03 5CH-CH-04 5CH-CH-05 5CH-CH-06 5Ch-CH-07 5CH-CH-08 5CW-P-02 5CW-P-03 5CW-P-04 5CW-P-05 5CW-P-06 5CW-P-07 5CW-P-08 9CH-CH-13 9CH-CH-12 9CH-CH-11 9CH-CH-10 9CH-CH-09 9CH-CH-16 9CH-CH-15 9CW-P-14 9CW-P-13 9CW-P-12 9CW-P-11 9CW-P-10 9CW-P-09 Stand-by 9CW-P-16 9CW-P-17 Trane UPCM TDB TWB TET TET TET TET Max. EWT = 38.4 ?C Max. LWT= 32.8 ?C Max. EWT = 38.4 ?C Max. LWT= 32.8 ?C Double-Bundle Condenser Heat Recovery for Warm Water System Cooling Load Evaporator Heating Load Heat Recovery Condenser Water-cooled Condenser Chilled Water Pump Condenser Water Pump Heat Recovery Pump Auxiliary Heat Source Cooling Tower way 3 - HR Warm & Hot Water System Schematic VFD VFD VFD 29.4?C WWR 37?C WWS VFD VFD 70?C HWR 90?C HWS HW-B-01 HW-B-05 HW-B-04 HW-B-03 HW-B-02 HW-P-01 HW-P-02 HR-P-04 HR-P-05 9CH-CH-15 9CH-CH-16 HTX HR-P-01 HR-P-02 HR-P-03 PDT TET TET TET TET TET PDT Electric Hot Water Boilers with 9-Step Register Heater Auto Temperature Control PDT
系统图案.ppt
下载此电子书资料需要扣除0点,